TMV servicing for hospitals and clinics

TMV Servicing Specialists arranges TMV servicing for hospitals, clinics and surgeries across the UK. The work follows the in-service testing set out in the D 08 supplement to HTM 04-01, and every valve is recorded in a form your water safety group can use.

A thermostatic mixing valve with a temperature test gauge fitted to its outlet

TMV work in healthcare estates

Healthcare buildings hold some of the most demanding water systems anywhere. Hot water has to be stored and circulated hot enough to control Legionella and Pseudomonas, yet patients at wash hand basins, showers and baths must be protected from scalding. Thermostatic mixing valves resolve that conflict at the outlet, and HTM 04-01 treats them as safety devices with a defined testing regime.

This page is for estates and facilities managers in NHS trusts and health boards, private hospitals, independent clinics, GP practices, dental surgeries, hospices and day surgery units. It suits sites that need routine D 08 in-service tests carried out and recorded, whether across a few consulting rooms or a ward block.

Where your valves are failing tests repeatedly or the site has a mix of unknown valve types, a survey or fault-finding visit is a better first step. New clinical wash hand basins and refurbished wards need commissioning, which records the baseline that later in-service tests are measured against.

What in-service testing covers

Visits follow the shape of the D 08 Chapter 11 in-service test, adapted to what your written scheme asks for.

  • Mixed temperature at the outletThe outlet temperature is measured and compared with the set point and with the reading recorded at commissioning.
  • Supply temperaturesHot and cold supply temperatures are taken at the valve so drift caused by the system can be told apart from drift in the valve.
  • Cold supply isolation testThe cold feed is isolated to confirm the valve shuts off or reduces to a trickle, then restored to check recovery, commonly within 2°C of the earlier reading.
  • Strainer and check valve serviceStrainers are cleaned and check valves inspected, at the interval the scheme sets or annually as a default.
  • Drift-based intervalsResults are used to confirm or shorten the next test date, in line with Annex F of D 08.
  • Outlet and valve labellingEach valve is identified by its room or asset number so results can be matched to your register.
  • Exception reportingFailed or borderline valves are flagged separately so the water safety group can act on them quickly.

Planning around clinical areas

  • Speak to infection prevention

    Some areas need specific cleaning of tools, temporary removal from use or sign-off before and after work on outlets.

  • Agree ward access windows

    Wards and theatres have their own routines. Plan the visit around ward rounds, clinics and patient flow.

  • Share your asset list

    A current list of valves with locations and commissioning dates lets the engineer work to your numbering.

  • Confirm your scheme intervals

    Your written scheme or water safety plan should state test frequencies and target temperatures for each outlet type.

Guidance across the four nations

  • England uses HTM 04-01

    Part B covers operational management of water systems, and the D 08 supplement sets the TMV performance and testing requirements.

  • Scotland and Wales have their own versions

    NHS Scotland follows SHTM 04-01 and NHS Wales follows WHTM 04-01, both broadly matching the English guidance.

  • Northern Ireland follows its own adoption

    Health and social care estates in Northern Ireland apply the HTM guidance through their own arrangements. Check what your trust specifies.

  • Dental and GP surgeries are healthcare too

    Smaller practices are not exempt from managing scald and Legionella risk. A short annual cycle of checks is often enough when recorded properly.

  • Clinical basins are a special case

    Some clinical wash hand basins have no plug and are used for hand hygiene only. Your water safety group decides whether a TMV is needed there.

From enquiry to test records

  1. 1

    Enquiry by form

    Tell us the site type, location, number of valves, and any permits or infection control steps that apply.

  2. 2

    Engineer matched

    Alex matches the job to a partner engineer who can work to your scheme and access arrangements.

  3. 3

    Price confirmed

    The price depends on valve numbers, access windows and any out-of-hours requirement, and is agreed before work starts.

  4. 4

    Testing on site

    Valves are tested and serviced in an agreed order, with each outlet returned to use once it passes.

  5. 5

    Results to the water safety group

    You should expect per-valve readings, fail-safe results, service records and an exceptions list.

Healthcare TMV questions

See all questions

What are the D 08 test intervals?

D 08 suggests tests at about 6-8 weeks and 12-15 weeks after commissioning, then an interval set by how much the valve drifts, often around 24-28 weeks for stable valves.

Do dental surgeries need TMVs?

Where patients or staff could be scalded at a basin or shower, a TMV is the usual control. Your risk assessment decides which outlets need one.

Can testing be done out of hours?

Ask in your enquiry. Whether a partner engineer can work evenings or weekends depends on the area and is confirmed with the price.

Are results in a format we can upload?

Tell us the format your scheme or software uses and we will aim to match it, by asset number where you have them.

What maximum temperatures apply?

D 08 commonly quotes 41°C for showers and washbasins, 38°C for bidets and 44°C for baths, with lower settings allowed by risk assessment.

Is this suitable for private hospitals?

Yes. Independent healthcare providers usually follow the same HTM guidance as the NHS for their water systems.

Who decides if a failing valve is replaced?

You do. The engineer reports the failure and options, and nothing beyond the agreed scope is done without your approval.