TMV regulations and guidance in the UK
There is no single law that says how often a thermostatic mixing valve must be serviced. Instead, a mix of health and safety law, building regulations, healthcare guidance, product standards and water fittings rules sets out who is responsible and what good practice looks like. This guide walks through each piece and notes where England, Scotland, Wales and Northern Ireland differ.
The legal starting point
In Great Britain, the Health and Safety at Work etc. Act 1974 places duties on employers and on people in control of premises to protect employees and others, including residents, patients, pupils, guests and tenants, from risks so far as is reasonably practicable. Northern Ireland has equivalent duties under its own health and safety legislation. Scalding from hot water outlets is a recognised risk, and Legionella from poorly controlled water systems is another.
The law does not name thermostatic mixing valves or set a servicing frequency. What it requires is a suitable and sufficient risk assessment, sensible control measures, and a way of showing those controls are working. Where a risk assessment identifies a scalding risk, fitting TMVs is a common control. Once fitted, the valves become part of the control system, so they need to be maintained, tested and recorded like any other safety-critical equipment. The interval and method are set by the risk assessment and the site's written scheme, informed by the guidance below.
HSE also publishes guidance on managing scalding and hot surface risks in health and social care, which explains when it expects water to be temperature-controlled at outlets used by vulnerable people.
Healthcare guidance: HTM 04-01, SHTM and WHTM
Healthcare buildings have the most detailed guidance on TMVs, and it is widely borrowed by care providers and other sectors.
-
HTM 04-01 (England)
Health Technical Memorandum 04-01 covers safe water in healthcare premises. Part B deals with operational management, including how water safety is organised and recorded. Hospitals and other NHS and independent healthcare providers in England work to it.
-
The D 08 supplement
D 08 is the performance specification for thermostatic mixing valves in healthcare. It sets the recommended maximum mixed temperatures for different outlets, the in-service testing method (Chapter 11) and the approach to setting test intervals based on each valve's performance (Annex F).
-
SHTM 04-01 (Scotland)
Scottish Health Technical Memorandum 04-01 is the equivalent guidance for NHS Scotland and healthcare premises there.
-
WHTM 04-01 (Wales)
Welsh Health Technical Memorandum 04-01 does the same job for NHS Wales.
-
Northern Ireland
Health and social care estates in Northern Ireland follow their own adoption of the HTM guidance, published for that system rather than by the Department of Health in England.
Product standards and the TMV2 and TMV3 schemes
-
BS EN 1111 and BS EN 1287
These European standards set performance tests for thermostatic mixing valves on high pressure (BS EN 1111) and low pressure (BS EN 1287) supplies, covering temperature stability, flow and response to supply failure.
-
TMV2
The TMV2 scheme approves valves for domestic-type use, tested against BS EN 1111 or BS EN 1287. It is the scheme usually referred to for baths in new homes.
-
TMV3
The TMV3 scheme approves valves to a higher performance level based on the NHS D 08 specification. It is the scheme usually specified for healthcare and similar settings where users are more vulnerable.
-
Matching the approval to the site
A valve's approval covers particular uses and supply pressures. Some valves hold both TMV2 and TMV3 approval. What matters is that the approval fits the setting and the site's actual hot and cold pressures. Our TMV2 vs TMV3 guide explains the difference.
Building regulations and bath temperatures
In England, Part G of the Building Regulations requires the hot water supplied to a bath in a new home, or in a home formed by a change of use, to be limited to 48°C. Wales has its own Part G with a matching requirement. A TMV or thermostatic bath filler is the usual way to meet it. Scotland's building standards set a similar limit for baths in new homes. These rules apply when the work is done; they do not set an ongoing servicing frequency, but a valve that no longer holds its temperature no longer does the job it was fitted for.
Housing law adds a further layer for rented homes. In England, the Housing Health and Safety Rating System includes scalds and hot surfaces among its hazards, and in Wales the fitness standards under the Renting Homes legislation draw on the same approach. Scotland has its Repairing Standard for private rented homes, and all four nations license houses in multiple occupation under their own laws. None of these names a TMV directly, but they explain why landlords and housing providers are asked to show that hot water risks are controlled.
Legionella guidance: L8 and HSG274
In Great Britain, the HSE Approved Code of Practice L8 and its technical guidance HSG274, Part 2 of which covers hot and cold water systems, set out how to assess and control Legionella. HSENI publishes the Northern Ireland equivalent. The guidance expects stored hot water to be kept at about 60°C and distributed so that outlets reach at least 50°C within a minute, or 55°C in healthcare premises.
TMVs sit right where scald control and Legionella control meet. The guidance asks for mixed-water pipework to be kept short, valves to be fitted close to the outlets they serve, and little-used outlets to be flushed and recorded. Our guide to TMVs and Legionella goes through the practical points.
Water fittings rules and care regulators
Two more sets of rules affect TMVs, depending on where the building is and what it is used for.
-
England and Wales
The Water Supply (Water Fittings) Regulations 1999 require fittings to be suitable, correctly installed and protected against backflow, which includes the check valves on TMV inlets.
-
Scotland
The Scottish Water Byelaws 2014 apply the same principles to installations connected to the public supply in Scotland.
-
Northern Ireland
The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009 apply there.
-
Care regulators
Care services are inspected by the CQC in England, the Care Inspectorate in Scotland, Care Inspectorate Wales and the RQIA in Northern Ireland. Inspectors look for evidence that risks such as scalding are assessed and controlled, which in practice often means up-to-date TMV test records.
Questions about TMV rules
Is TMV servicing a legal requirement?
The law requires risks to be assessed and controlled, not TMV servicing at a set frequency. Once TMVs are part of your controls, you need to be able to show they are maintained and working.
Do I have to follow HTM 04-01 if I am not a hospital?
HTM 04-01 is written for healthcare premises, but many care providers and other duty holders use its D 08 testing approach as a benchmark because it is clear and well understood.
Which approval does a new home bath need?
Building regulations set the 48°C limit rather than a particular scheme, but valves with TMV2 approval are commonly used for domestic baths.
Does the risk assessment have to mention TMVs?
Where TMVs are used to control scalding risk, the risk assessment and the written scheme should say where they are, what temperature they are set to and how they are tested.
What do inspectors want to see?
Usually a list of valves, set temperatures, test results, fail-safe outcomes and the actions taken when a valve failed. Clear, dated records per valve are the easiest way to show that.
Are the rules different in Scotland, Wales and Northern Ireland?
The principles are the same across the UK, but the healthcare guidance, building rules, water fittings rules and care regulators are each set separately in each nation.
Related pages
- TMV asset registersA list of every valve, where it is and how it is set, to sit alongside the risk assessment.
- TMV surveysA look at what is installed and how it compares with current guidance.
- Care homesTMV work for residential and nursing care settings.
- Landlords and HMOsTMVs in rented homes and houses in multiple occupation.
Need valves tested against your scheme?
Send an enquiry with the number of valves, the type of site and the guidance you work to. We will match the job to a partner engineer and confirm the price before work starts.
Send an enquiry